{"product_id":"zkteco-ex16-elevator-floor-extension-board-add-16-floors-to-ec10-elevator-controller-scalable-rs485-access-control","title":"ZKTeco EX16 Elevator Floor Extension Board | Add 16 Floors to EC10 Elevator Controller – Scalable RS485 Access Control","description":"\u003cp data-start=\"468\" data-end=\"784\"\u003eThe \u003cstrong data-start=\"472\" data-end=\"487\"\u003eZKTeco EX16\u003c\/strong\u003e is a floor extension module specifically designed to expand the capabilities of the \u003cstrong data-start=\"572\" data-end=\"617\"\u003eZKTeco EC10 Elevator Access Control Panel\u003c\/strong\u003e. Each EX16 board adds \u003cstrong data-start=\"640\" data-end=\"676\"\u003econtrol for 16 additional floors\u003c\/strong\u003e, allowing administrators to restrict or grant elevator access by user credentials, time schedules, or both.\u003c\/p\u003e\n\u003cp data-start=\"786\" data-end=\"1039\"\u003eWith support for \u003cstrong data-start=\"803\" data-end=\"834\"\u003eup to 3 EX16 units per EC10\u003c\/strong\u003e, this system allows control of \u003cstrong data-start=\"866\" data-end=\"901\"\u003eup to 58 floors per EC10 bundle\u003c\/strong\u003e. The EX16 connects via \u003cstrong data-start=\"925\" data-end=\"948\"\u003eRS485 communication\u003c\/strong\u003e and is addressable via DIP switch settings for ease of deployment in multi-floor projects.\u003c\/p\u003e\n\u003cp data-start=\"1041\" data-end=\"1282\"\u003eWhether managing residential high-rises, commercial towers, or mixed-use complexes, the EX16 delivers \u003cstrong data-start=\"1143\" data-end=\"1200\"\u003eaffordable, secure, and scalable floor access control\u003c\/strong\u003e, fully integrated with biometric, RFID, or password-based authentication methods.\u003cimg role=\"presentation\" data-image-zoom-target=\"true\" class=\"zoomImg\" src=\"https:\/\/secusafe.com.au\/cdn\/shop\/files\/c3e6047f-9755-409b-abc8-2efc58dae8e7_41f39f11-3212-4563-a6bc-cbaf0d355a65_1024x1024@2x.png?v=1755173558\"\u003e\u003c\/p\u003e\n\u003chr data-start=\"1284\" data-end=\"1287\"\u003e\n\u003ch3 data-start=\"1289\" data-end=\"1321\"\u003eWhat’s Included in the Box\u003c\/h3\u003e\n\u003cul data-start=\"1322\" data-end=\"1476\"\u003e\n\u003cli data-start=\"1322\" data-end=\"1372\"\u003e\n\u003cp data-start=\"1324\" data-end=\"1372\"\u003e1 × ZKTeco EX16 Elevator Floor Extension Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1373\" data-end=\"1392\"\u003e\n\u003cp data-start=\"1375\" data-end=\"1392\"\u003eRS485 Connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1393\" data-end=\"1421\"\u003e\n\u003cp data-start=\"1395\" data-end=\"1421\"\u003eDIP Switch Configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1422\" data-end=\"1446\"\u003e\n\u003cp data-start=\"1424\" data-end=\"1446\"\u003eMounting Accessories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1447\" data-end=\"1476\"\u003e\n\u003cp data-start=\"1449\" data-end=\"1476\"\u003eInstallation Instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1478\" data-end=\"1481\"\u003e\n\u003ch3 data-start=\"1483\" data-end=\"1502\"\u003eMain Features\u003c\/h3\u003e\n\u003cul data-start=\"1503\" data-end=\"2426\"\u003e\n\u003cli data-start=\"1503\" data-end=\"1597\"\u003e\n\u003cp data-start=\"1505\" data-end=\"1597\"\u003e\u003cstrong data-start=\"1505\" data-end=\"1529\"\u003eAdds 16 Floor Relays\u003c\/strong\u003e: Expands elevator control by 16 floors when connected to an EC10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1598\" data-end=\"1727\"\u003e\n\u003cp data-start=\"1600\" data-end=\"1727\"\u003e\u003cstrong data-start=\"1600\" data-end=\"1625\"\u003eScalable Architecture\u003c\/strong\u003e: A single EC10 can support up to \u003cstrong data-start=\"1659\" data-end=\"1675\"\u003e3 EX16 units\u003c\/strong\u003e, extending access control to \u003cstrong data-start=\"1705\" data-end=\"1724\"\u003e58 total floors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1728\" data-end=\"1849\"\u003e\n\u003cp data-start=\"1730\" data-end=\"1849\"\u003e\u003cstrong data-start=\"1730\" data-end=\"1757\"\u003eFlexible Access Control\u003c\/strong\u003e: Supports fingerprint, proximity card, and\/or PIN code authentication via connected EC10.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1850\" data-end=\"1939\"\u003e\n\u003cp data-start=\"1852\" data-end=\"1939\"\u003e\u003cstrong data-start=\"1852\" data-end=\"1879\"\u003eTime-Based Restrictions\u003c\/strong\u003e: Configure floor access using pre-defined time schedules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1940\" data-end=\"2028\"\u003e\n\u003cp data-start=\"1942\" data-end=\"2028\"\u003e\u003cstrong data-start=\"1942\" data-end=\"1958\"\u003ePassage Mode\u003c\/strong\u003e: Allow unrestricted floor access during business or visiting hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2029\" data-end=\"2122\"\u003e\n\u003cp data-start=\"2031\" data-end=\"2122\"\u003e\u003cstrong data-start=\"2031\" data-end=\"2061\"\u003eSecure RS485 Communication\u003c\/strong\u003e: Reliable and long-range data transfer to EC10 controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2123\" data-end=\"2219\"\u003e\n\u003cp data-start=\"2125\" data-end=\"2219\"\u003e\u003cstrong data-start=\"2125\" data-end=\"2155\"\u003eAddressable via DIP Switch\u003c\/strong\u003e: Ensures proper module identification and prevents conflicts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2220\" data-end=\"2323\"\u003e\n\u003cp data-start=\"2222\" data-end=\"2323\"\u003e\u003cstrong data-start=\"2222\" data-end=\"2246\"\u003eSeamless Integration\u003c\/strong\u003e: Works with EC10 and is managed through the same elevator access software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2324\" data-end=\"2426\"\u003e\n\u003cp data-start=\"2326\" data-end=\"2426\"\u003e\u003cstrong data-start=\"2326\" data-end=\"2358\"\u003eIdeal for High-Rise Projects\u003c\/strong\u003e: Compact and powerful solution for large building elevator systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2428\" data-end=\"2431\"\u003e\n\u003ch3 data-start=\"2433\" data-end=\"2462\"\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2464\" data-end=\"3110\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2464\" data-end=\"2535\"\u003e\n\u003ctr data-start=\"2464\" data-end=\"2535\"\u003e\n\u003cth data-start=\"2464\" data-end=\"2492\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2466\" data-end=\"2483\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2492\" data-end=\"2535\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2494\" data-end=\"2505\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2607\" data-end=\"3110\"\u003e\n\u003ctr data-start=\"2607\" data-end=\"2678\"\u003e\n\u003ctd data-start=\"2607\" data-end=\"2634\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2634\" data-end=\"2678\"\u003eZKTeco EX16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2679\" data-end=\"2750\"\u003e\n\u003ctd data-start=\"2679\" data-end=\"2706\" data-col-size=\"sm\"\u003eControlled Floors\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2706\" data-end=\"2750\"\u003e16 (via 16 relay outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2751\" data-end=\"2822\"\u003e\n\u003ctd data-start=\"2751\" data-end=\"2778\" data-col-size=\"sm\"\u003eCommunication to EC10\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2778\" data-end=\"2822\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2823\" data-end=\"2894\"\u003e\n\u003ctd data-start=\"2823\" data-end=\"2850\" data-col-size=\"sm\"\u003eAddress Configuration\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2850\" data-end=\"2894\"\u003eDIP Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2895\" data-end=\"2966\"\u003e\n\u003ctd data-start=\"2895\" data-end=\"2922\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2922\" data-end=\"2966\"\u003e12V DC 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2967\" data-end=\"3038\"\u003e\n\u003ctd data-start=\"2967\" data-end=\"2994\" data-col-size=\"sm\"\u003eDimensions (L×D×H)\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2994\" data-end=\"3038\"\u003e160 × 106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3039\" data-end=\"3110\"\u003e\n\u003ctd data-start=\"3039\" data-end=\"3066\" data-col-size=\"sm\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3066\" data-end=\"3110\"\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3112\" data-end=\"3115\"\u003e\n\u003ch3 data-start=\"3117\" data-end=\"3143\"\u003eWarranty Information\u003c\/h3\u003e\n\u003cp data-start=\"3144\" data-end=\"3344\"\u003emanufactures warranty applied\u003c\/p\u003e\n\u003chr data-start=\"3346\" data-end=\"3349\"\u003e\n\u003ch3 data-start=\"3351\" data-end=\"3374\"\u003eBrand Description\u003c\/h3\u003e\n\u003cp data-start=\"3375\" data-end=\"3715\"\u003e\u003cstrong data-start=\"3375\" data-end=\"3385\"\u003eZKTeco\u003c\/strong\u003e is a trusted name in biometric and access control solutions, offering scalable and reliable products for commercial and institutional security. The EX16 is part of ZKTeco’s modular elevator control ecosystem, providing smart, secure, and cost-effective solutions for managing floor-level access in modern vertical infrastructure.\u003c\/p\u003e\n\u003chr data-start=\"3717\" data-end=\"3720\"\u003e\n\u003ch3 data-start=\"3722\" data-end=\"3731\"\u003eSKU\u003c\/h3\u003e\n\u003cp data-start=\"3732\" data-end=\"3740\"\u003e\u003cstrong data-start=\"3732\" data-end=\"3740\"\u003eEX16\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3742\" data-end=\"3745\"\u003e\n\u003ch3 data-start=\"3747\" data-end=\"3776\"\u003ePractical Use Scenarios\u003c\/h3\u003e\n\u003cul data-start=\"3777\" data-end=\"4232\"\u003e\n\u003cli data-start=\"3777\" data-end=\"3876\"\u003e\n\u003cp data-start=\"3779\" data-end=\"3876\"\u003e\u003cstrong data-start=\"3779\" data-end=\"3814\"\u003eHigh-Rise Residential Buildings\u003c\/strong\u003e: Extend elevator access per unit or resident authorization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3877\" data-end=\"3964\"\u003e\n\u003cp data-start=\"3879\" data-end=\"3964\"\u003e\u003cstrong data-start=\"3879\" data-end=\"3896\"\u003eOffice Towers\u003c\/strong\u003e: Restrict staff and visitor access to designated business floors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3965\" data-end=\"4056\"\u003e\n\u003cp data-start=\"3967\" data-end=\"4056\"\u003e\u003cstrong data-start=\"3967\" data-end=\"3977\"\u003eHotels\u003c\/strong\u003e: Assign temporary floor access based on guest credentials and stay duration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4057\" data-end=\"4144\"\u003e\n\u003cp data-start=\"4059\" data-end=\"4144\"\u003e\u003cstrong data-start=\"4059\" data-end=\"4072\"\u003eHospitals\u003c\/strong\u003e: Control access to specific wards, surgical suites, and admin floors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4145\" data-end=\"4232\"\u003e\n\u003cp data-start=\"4147\" data-end=\"4232\"\u003e\u003cstrong data-start=\"4147\" data-end=\"4172\"\u003eGovernment Facilities\u003c\/strong\u003e: Ensure only authorized personnel can access secure levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4234\" data-end=\"4237\"\u003e\n\u003ch3 data-start=\"4239\" data-end=\"4280\"\u003eDatasheets \u0026amp; Downloadable Resources\u003c\/h3\u003e\n\u003cp data-start=\"4281\" data-end=\"4426\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/EX16.pdf?v=1755288730\"\u003eZKTeco EX16\u003c\/a\u003e\u003c\/p\u003e\n\u003chr data-start=\"4428\" data-end=\"4431\"\u003e\n\u003ch3 data-start=\"4433\" data-end=\"4491\"\u003eExcellence for the Australian and New Zealand Market\u003c\/h3\u003e\n\u003cp data-start=\"4492\" data-end=\"4640\"\u003eThe \u003cstrong data-start=\"4496\" data-end=\"4511\"\u003eZKTeco EX16\u003c\/strong\u003e extension board is engineered to meet the high standards of elevator access control expected across Australia and New Zealand:\u003c\/p\u003e\n\u003cul data-start=\"4641\" data-end=\"5087\"\u003e\n\u003cli data-start=\"4641\" data-end=\"4729\"\u003e\n\u003cp data-start=\"4643\" data-end=\"4729\"\u003e\u003cstrong data-start=\"4643\" data-end=\"4663\"\u003eCompliance-Ready\u003c\/strong\u003e: Supports advanced security protocols through EC10 integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4730\" data-end=\"4821\"\u003e\n\u003cp data-start=\"4732\" data-end=\"4821\"\u003e\u003cstrong data-start=\"4732\" data-end=\"4751\"\u003eScalable Design\u003c\/strong\u003e: Ideal for ANZ commercial and multi-level residential construction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4822\" data-end=\"4958\"\u003e\n\u003cp data-start=\"4824\" data-end=\"4958\"\u003e\u003cstrong data-start=\"4824\" data-end=\"4857\"\u003eGenuine Distribution Channels\u003c\/strong\u003e: Products sourced through authorized partners ensure warranty coverage and firmware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4959\" data-end=\"5087\"\u003e\n\u003cp data-start=\"4961\" data-end=\"5087\"\u003e\u003cstrong data-start=\"4961\" data-end=\"4987\"\u003eLocal Support Services\u003c\/strong\u003e: Warranty and integration support is locally managed, reducing downtime and ensuring peace of mind.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5089\" data-end=\"5092\"\u003e\n\u003ch3 data-start=\"5094\" data-end=\"5123\"\u003eFAQs (Product Code: EX16)\u003c\/h3\u003e\n\u003col data-start=\"5125\" data-end=\"6016\"\u003e\n\u003cli data-start=\"5125\" data-end=\"5294\"\u003e\n\u003cp data-start=\"5128\" data-end=\"5294\"\u003e\u003cstrong data-start=\"5128\" data-end=\"5203\"\u003eWhat is the maximum number of EX16 boards that can connect to one EC10?\u003c\/strong\u003e\u003cbr data-start=\"5203\" data-end=\"5206\"\u003eEach EC10 supports \u003cstrong data-start=\"5228\" data-end=\"5251\"\u003eup to 3 EX16 boards\u003c\/strong\u003e, enabling control for up to \u003cstrong data-start=\"5280\" data-end=\"5293\"\u003e58 floors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5296\" data-end=\"5437\"\u003e\n\u003cp data-start=\"5299\" data-end=\"5437\"\u003e\u003cstrong data-start=\"5299\" data-end=\"5348\"\u003eWhat type of communication does the EX16 use?\u003c\/strong\u003e\u003cbr data-start=\"5348\" data-end=\"5351\"\u003eThe EX16 uses \u003cstrong data-start=\"5368\" data-end=\"5377\"\u003eRS485\u003c\/strong\u003e communication to connect reliably with the EC10 controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5439\" data-end=\"5620\"\u003e\n\u003cp data-start=\"5442\" data-end=\"5620\"\u003e\u003cstrong data-start=\"5442\" data-end=\"5491\"\u003eCan EX16 modules be configured independently?\u003c\/strong\u003e\u003cbr data-start=\"5491\" data-end=\"5494\"\u003eYes, each EX16 is \u003cstrong data-start=\"5515\" data-end=\"5547\"\u003eaddressable via DIP switches\u003c\/strong\u003e, allowing multiple units to operate on the same system without conflict.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5622\" data-end=\"5801\"\u003e\n\u003cp data-start=\"5625\" data-end=\"5801\"\u003e\u003cstrong data-start=\"5625\" data-end=\"5689\"\u003eDoes the EX16 support fingerprint or card access on its own?\u003c\/strong\u003e\u003cbr data-start=\"5689\" data-end=\"5692\"\u003eNo, the EX16 is an extension module. It \u003cstrong data-start=\"5735\" data-end=\"5756\"\u003erequires the EC10\u003c\/strong\u003e to operate and process authentication logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5803\" data-end=\"6016\"\u003e\n\u003cp data-start=\"5806\" data-end=\"6016\"\u003e\u003cstrong data-start=\"5806\" data-end=\"5877\"\u003eIs the EX16 suitable for commercial elevator systems in high-rises?\u003c\/strong\u003e\u003cbr data-start=\"5877\" data-end=\"5880\"\u003eAbsolutely. The EX16 is \u003cstrong data-start=\"5907\" data-end=\"5932\"\u003especifically designed\u003c\/strong\u003e to extend floor-level control in multi-story buildings and large elevator networks.\u003c\/p\u003e\n\u003ch3 data-start=\"3341\" data-end=\"3364\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003eplease contact CCTV TRADIE for stock availability\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"CCTV Tradie","offers":[{"title":"Default Title","offer_id":44530402787431,"sku":"EX16-SEC","price":255.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/8268\/2471\/files\/c3e6047f-9755-409b-abc8-2efc58dae8e7_1024x1024_2x_eaa49a7a-9d73-4e86-8602-e00538e23519.webp?v=1788077316","url":"https:\/\/shop.underbrella.com.au\/products\/zkteco-ex16-elevator-floor-extension-board-add-16-floors-to-ec10-elevator-controller-scalable-rs485-access-control","provider":"UnderBrella","version":"1.0","type":"link"}