{"product_id":"system-sensor-2012j-photoelectric-smoke-alarm-12-24vdc-interconnectable-form-c-relay-hush-feature-model-2012j","title":"System Sensor 2012J Photoelectric Smoke Alarm – 12\/24VDC, Interconnectable, Form C Relay, Hush Feature | Model 2012J","description":"\u003cp data-start=\"387\" data-end=\"769\"\u003eProtect lives and property with the \u003cstrong data-start=\"423\" data-end=\"472\"\u003eSystem Sensor 2012J Photoelectric Smoke Alarm\u003c\/strong\u003e, a high-performance smoke detection solution designed for demanding residential and commercial applications. This advanced smoke alarm operates on 12-24VDC power and features photoelectric sensing technology, offering superior sensitivity to slow smouldering fires while reducing nuisance alarms.\u003c\/p\u003e\n\u003cp data-start=\"387\" data-end=\"769\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/Screenshot2025-07-12140955.png?v=1752293408\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp data-start=\"771\" data-end=\"1199\"\u003eCompact, sleek, and easy to install, the 2012J delivers exceptional reliability and a suite of advanced features. Equipped with a built-in test\/hush button, visible LED status indicators, and a Form ‘C’ relay, it ensures both audible and visual alerts for maximum safety. With the capacity to interconnect up to 24 units, the 2012J is ideal for installations in apartments, nursing homes, hotels, and other multi-unit dwellings.\u003c\/p\u003e\n\u003cp data-start=\"1201\" data-end=\"1473\"\u003eThe System Sensor 2012J meets the rigorous AS 3786 standard, ensuring compliance with Australian safety regulations. Its easy-access chamber design allows for straightforward maintenance and cleaning, helping extend the life of the device and maintain optimal performance.\u003c\/p\u003e\n\u003cp data-start=\"1201\" data-end=\"1473\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/Screenshot_2025-07-12_141434.png?v=1752293685\" alt=\"\"\u003e\u003c\/p\u003e\n\u003chr data-start=\"1475\" data-end=\"1478\"\u003e\n\u003ch2 data-start=\"1480\" data-end=\"1513\"\u003e\u003cstrong data-start=\"1483\" data-end=\"1513\"\u003eWhat's Included in the Box\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1515\" data-end=\"1623\"\u003e\n\u003cli data-start=\"1515\" data-end=\"1562\"\u003e\n\u003cp data-start=\"1517\" data-end=\"1562\"\u003eSystem Sensor 2012J Photoelectric Smoke Alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1578\"\u003e\n\u003cp data-start=\"1565\" data-end=\"1578\"\u003eMounting ring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1579\" data-end=\"1606\"\u003e\n\u003cp data-start=\"1581\" data-end=\"1606\"\u003eInstallation instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1607\" data-end=\"1623\"\u003e\n\u003cp data-start=\"1609\" data-end=\"1623\"\u003eWiring diagram\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1625\" data-end=\"1628\"\u003e\n\u003ch2 data-start=\"1630\" data-end=\"1650\"\u003e\u003cstrong data-start=\"1633\" data-end=\"1650\"\u003eMain Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1652\" data-end=\"1758\"\u003e✅ \u003cstrong data-start=\"1654\" data-end=\"1681\"\u003ePhotoelectric Detection\u003c\/strong\u003e\u003cbr data-start=\"1681\" data-end=\"1684\"\u003eHighly effective at sensing smouldering fires while reducing false alarms.\u003c\/p\u003e\n\u003cp data-start=\"1760\" data-end=\"1832\"\u003e✅ \u003cstrong data-start=\"1762\" data-end=\"1784\"\u003e12\/24VDC Operation\u003c\/strong\u003e\u003cbr data-start=\"1784\" data-end=\"1787\"\u003eCompatible with standard low-voltage systems.\u003c\/p\u003e\n\u003cp data-start=\"1834\" data-end=\"1919\"\u003e✅ \u003cstrong data-start=\"1836\" data-end=\"1852\"\u003eHUSH Feature\u003c\/strong\u003e\u003cbr data-start=\"1852\" data-end=\"1855\"\u003eTemporarily silences nuisance alarms with a simple button press.\u003c\/p\u003e\n\u003cp data-start=\"1921\" data-end=\"2001\"\u003e✅ \u003cstrong data-start=\"1923\" data-end=\"1943\"\u003eTest Push Button\u003c\/strong\u003e\u003cbr data-start=\"1943\" data-end=\"1946\"\u003eConvenient testing for functionality and alarm sounder.\u003c\/p\u003e\n\u003cp data-start=\"2003\" data-end=\"2111\"\u003e✅ \u003cstrong data-start=\"2005\" data-end=\"2030\"\u003eForm ‘C’ Relay Output\u003c\/strong\u003e\u003cbr data-start=\"2030\" data-end=\"2033\"\u003e1A @ 30VDC\/AC relay contacts activate upon local alarm or interconnect signal.\u003c\/p\u003e\n\u003cp data-start=\"2113\" data-end=\"2209\"\u003e✅ \u003cstrong data-start=\"2115\" data-end=\"2142\"\u003eInterconnect Capability\u003c\/strong\u003e\u003cbr data-start=\"2142\" data-end=\"2145\"\u003eConnect up to 24 smoke alarms for comprehensive system coverage.\u003c\/p\u003e\n\u003cp data-start=\"2211\" data-end=\"2375\"\u003e✅ \u003cstrong data-start=\"2213\" data-end=\"2244\"\u003eVisual \u0026amp; Audible Indicators\u003c\/strong\u003e\u003cbr data-start=\"2244\" data-end=\"2247\"\u003eLED signals for standby, alarm, faults, and test mode with synchronized or asynchronous audible signals depending on fault type.\u003c\/p\u003e\n\u003cp data-start=\"2377\" data-end=\"2468\"\u003e✅ \u003cstrong data-start=\"2379\" data-end=\"2411\"\u003eChamber Integrity Monitoring\u003c\/strong\u003e\u003cbr data-start=\"2411\" data-end=\"2414\"\u003eAutomatic chamber test to ensure detector reliability.\u003c\/p\u003e\n\u003cp data-start=\"2470\" data-end=\"2566\"\u003e✅ \u003cstrong data-start=\"2472\" data-end=\"2490\"\u003eCompact Design\u003c\/strong\u003e\u003cbr data-start=\"2490\" data-end=\"2493\"\u003eMeasures only 55 mm (H) x 135 mm (diameter) for unobtrusive installation.\u003c\/p\u003e\n\u003cp data-start=\"2568\" data-end=\"2642\"\u003e✅ \u003cstrong data-start=\"2570\" data-end=\"2589\"\u003e3-Year Warranty\u003c\/strong\u003e\u003cbr data-start=\"2589\" data-end=\"2592\"\u003eBacked by System Sensor’s solid warranty coverage.\u003c\/p\u003e\n\u003chr data-start=\"2644\" data-end=\"2647\"\u003e\n\u003ch2 data-start=\"2649\" data-end=\"2679\"\u003e\u003cstrong data-start=\"2652\" data-end=\"2679\"\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2681\" data-end=\"3400\"\u003e\n\u003cli data-start=\"2681\" data-end=\"2699\"\u003e\n\u003cp data-start=\"2683\" data-end=\"2699\"\u003e\u003cstrong data-start=\"2683\" data-end=\"2693\"\u003eModel:\u003c\/strong\u003e 2012J\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2700\" data-end=\"2732\"\u003e\n\u003cp data-start=\"2702\" data-end=\"2732\"\u003e\u003cstrong data-start=\"2702\" data-end=\"2718\"\u003eSensor Type:\u003c\/strong\u003e Photoelectric\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2733\" data-end=\"2771\"\u003e\n\u003cp data-start=\"2735\" data-end=\"2771\"\u003e\u003cstrong data-start=\"2735\" data-end=\"2757\"\u003eOperating Voltage:\u003c\/strong\u003e 10VDC ~ 30VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2772\" data-end=\"2814\"\u003e\n\u003cp data-start=\"2774\" data-end=\"2814\"\u003e\u003cstrong data-start=\"2774\" data-end=\"2792\"\u003eAlarm Current:\u003c\/strong\u003e Max. 65 mA @ 10-30VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2815\" data-end=\"2856\"\u003e\n\u003cp data-start=\"2817\" data-end=\"2856\"\u003e\u003cstrong data-start=\"2817\" data-end=\"2837\"\u003eStandby Current:\u003c\/strong\u003e Max. 60 μA average\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2857\" data-end=\"2911\"\u003e\n\u003cp data-start=\"2859\" data-end=\"2911\"\u003e\u003cstrong data-start=\"2859\" data-end=\"2884\"\u003eRelay Contact Rating:\u003c\/strong\u003e 1 Form C, 1A @ 30VDC or AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2912\" data-end=\"2949\"\u003e\n\u003cp data-start=\"2914\" data-end=\"2949\"\u003e\u003cstrong data-start=\"2914\" data-end=\"2931\"\u003eSound Output:\u003c\/strong\u003e 85 dBA @ 3 meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2950\" data-end=\"2983\"\u003e\n\u003cp data-start=\"2952\" data-end=\"2983\"\u003e\u003cstrong data-start=\"2952\" data-end=\"2974\"\u003eTemperature Range:\u003c\/strong\u003e 0℃ ~ 50℃\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2984\" data-end=\"3033\"\u003e\n\u003cp data-start=\"2986\" data-end=\"3033\"\u003e\u003cstrong data-start=\"2986\" data-end=\"3005\"\u003eHumidity Range:\u003c\/strong\u003e 5% ~ 93% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3034\" data-end=\"3081\"\u003e\n\u003cp data-start=\"3036\" data-end=\"3081\"\u003e\u003cstrong data-start=\"3036\" data-end=\"3051\"\u003eDimensions:\u003c\/strong\u003e 55 mm (H) x 135 mm (diameter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3082\" data-end=\"3105\"\u003e\n\u003cp data-start=\"3084\" data-end=\"3105\"\u003e\u003cstrong data-start=\"3084\" data-end=\"3095\"\u003eWeight:\u003c\/strong\u003e 220 grams\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3106\" data-end=\"3140\"\u003e\n\u003cp data-start=\"3108\" data-end=\"3140\"\u003e\u003cstrong data-start=\"3108\" data-end=\"3137\"\u003eMax Interconnected Units:\u003c\/strong\u003e 24\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3141\" data-end=\"3199\"\u003e\n\u003cp data-start=\"3143\" data-end=\"3199\"\u003e\u003cstrong data-start=\"3143\" data-end=\"3157\"\u003eWire Size:\u003c\/strong\u003e 0.75 mm² or larger (for interconnect bus)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3200\" data-end=\"3344\"\u003e\n\u003cp data-start=\"3202\" data-end=\"3225\"\u003e\u003cstrong data-start=\"3202\" data-end=\"3225\"\u003eMaximum Bus Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"3228\" data-end=\"3344\"\u003e\n\u003cli data-start=\"3228\" data-end=\"3286\"\u003e\n\u003cp data-start=\"3230\" data-end=\"3286\"\u003e\u003cstrong data-start=\"3230\" data-end=\"3240\"\u003e12VDC:\u003c\/strong\u003e Up to 2000 meters total (wire size dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3289\" data-end=\"3344\"\u003e\n\u003cp data-start=\"3291\" data-end=\"3344\"\u003e\u003cstrong data-start=\"3291\" data-end=\"3301\"\u003e24VDC:\u003c\/strong\u003e Bus length 4x that of 12VDC configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3345\" data-end=\"3376\"\u003e\n\u003cp data-start=\"3347\" data-end=\"3376\"\u003e\u003cstrong data-start=\"3347\" data-end=\"3361\"\u003eStandards:\u003c\/strong\u003e AS 3786 Listed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3377\" data-end=\"3400\"\u003e\n\u003cp data-start=\"3379\" data-end=\"3400\"\u003e\u003cstrong data-start=\"3379\" data-end=\"3392\"\u003eWarranty:\u003c\/strong\u003e 3 years\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3402\" data-end=\"3405\"\u003e\n\u003ch2 data-start=\"3407\" data-end=\"3434\"\u003e\u003cstrong data-start=\"3410\" data-end=\"3434\"\u003eWarranty Information\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3436\" data-end=\"3712\"\u003eThe System Sensor 2012J Photoelectric Smoke Alarm comes with a 3-year manufacturer’s warranty, covering defects in materials and workmanship under normal use. For warranty claims in Australia and New Zealand, customers can contact System Sensor directly for prompt assistance.\u003c\/p\u003e\n\u003chr data-start=\"3714\" data-end=\"3717\"\u003e\n\u003ch2 data-start=\"3719\" data-end=\"3741\"\u003e\u003cstrong data-start=\"3722\" data-end=\"3741\"\u003eAbout the Brand\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3743\" data-end=\"4076\"\u003e\u003cstrong data-start=\"3743\" data-end=\"3760\"\u003eSystem Sensor\u003c\/strong\u003e is a global leader in fire detection and life safety solutions. Known for technological innovation, superior product quality, and rigorous compliance with international standards, System Sensor products are trusted worldwide for protecting lives and property in residential, commercial, and industrial applications.\u003c\/p\u003e\n\u003chr data-start=\"4078\" data-end=\"4081\"\u003e\n\u003ch2 data-start=\"4083\" data-end=\"4093\"\u003e\u003cstrong data-start=\"4086\" data-end=\"4093\"\u003eSKU\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4095\" data-end=\"4104\"\u003e\u003cstrong data-start=\"4095\" data-end=\"4104\"\u003e2012J\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4106\" data-end=\"4109\"\u003e\n\u003ch2 data-start=\"4111\" data-end=\"4141\"\u003e\u003cstrong data-start=\"4114\" data-end=\"4141\"\u003ePractical Use Scenarios\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4143\" data-end=\"4677\"\u003e\n\u003cli data-start=\"4143\" data-end=\"4245\"\u003e\n\u003cp data-start=\"4145\" data-end=\"4245\"\u003e\u003cstrong data-start=\"4145\" data-end=\"4183\"\u003eApartments \u0026amp; Multi-Unit Residences\u003c\/strong\u003e\u003cbr data-start=\"4183\" data-end=\"4186\"\u003eIdeal for interconnected systems covering entire buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4247\" data-end=\"4369\"\u003e\n\u003cp data-start=\"4249\" data-end=\"4369\"\u003e\u003cstrong data-start=\"4249\" data-end=\"4289\"\u003eNursing Homes \u0026amp; Aged Care Facilities\u003c\/strong\u003e\u003cbr data-start=\"4289\" data-end=\"4292\"\u003eEnsures fast detection of smouldering fires while minimizing nuisance alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4371\" data-end=\"4482\"\u003e\n\u003cp data-start=\"4373\" data-end=\"4482\"\u003e\u003cstrong data-start=\"4373\" data-end=\"4404\"\u003eHotels \u0026amp; Hospitality Spaces\u003c\/strong\u003e\u003cbr data-start=\"4404\" data-end=\"4407\"\u003eDiscreet design complements any décor while delivering reliable protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4484\" data-end=\"4576\"\u003e\n\u003cp data-start=\"4486\" data-end=\"4576\"\u003e\u003cstrong data-start=\"4486\" data-end=\"4511\"\u003eCommercial Properties\u003c\/strong\u003e\u003cbr data-start=\"4511\" data-end=\"4514\"\u003ePerfect for low-voltage alarm systems requiring relay outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4578\" data-end=\"4677\"\u003e\n\u003cp data-start=\"4580\" data-end=\"4677\"\u003e\u003cstrong data-start=\"4580\" data-end=\"4601\"\u003eResidential Homes\u003c\/strong\u003e\u003cbr data-start=\"4601\" data-end=\"4604\"\u003ePeace of mind for homeowners seeking reliable, compliant smoke detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4679\" data-end=\"4682\"\u003e\n\u003ch2 data-start=\"4684\" data-end=\"4713\"\u003e\u003cstrong data-start=\"4687\" data-end=\"4713\"\u003eDatasheets \u0026amp; Resources\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"4715\" data-end=\"4879\"\u003e\n\u003cli data-start=\"4715\" data-end=\"4879\"\u003e\n\u003cp data-start=\"4717\" data-end=\"4879\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/2012J_Datasheet.pdf?v=1752293266\"\u003eSystem Sensor 2012J Smoke Alarm Datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4881\" data-end=\"4884\"\u003e\n\u003ch2 data-start=\"4886\" data-end=\"4945\"\u003e\u003cstrong data-start=\"4889\" data-end=\"4945\"\u003eExcellence for the Australian and New Zealand Market\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4947\" data-end=\"5647\"\u003eThe \u003cstrong data-start=\"4951\" data-end=\"5000\"\u003eSystem Sensor 2012J Photoelectric Smoke Alarm\u003c\/strong\u003e is fully compliant with \u003cstrong data-start=\"5025\" data-end=\"5036\"\u003eAS 3786\u003c\/strong\u003e, ensuring adherence to Australian safety standards and local building codes. It’s sourced exclusively through authorized representatives, guaranteeing authenticity and full manufacturer support. NDSS approval (where relevant) ensures the device meets regulatory requirements for residential and commercial installations. All warranty claims and product support for Australia and New Zealand are handled directly with System Sensor, providing local peace of mind and seamless service. Invest in safety equipment designed and optimized specifically for the unique needs of the Australian and New Zealand markets.\u003c\/p\u003e\n\u003chr data-start=\"5649\" data-end=\"5652\"\u003e\n\u003ch2 data-start=\"5654\" data-end=\"5679\"\u003e\u003cstrong data-start=\"5657\" data-end=\"5679\"\u003eFAQs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5681\" data-end=\"6004\"\u003e\u003cstrong data-start=\"5681\" data-end=\"5798\"\u003eQ1: Can the System Sensor 2012J smoke alarm (Model 2012J) be used in residential homes with a 12VDC power supply?\u003c\/strong\u003e\u003cbr data-start=\"5798\" data-end=\"5801\"\u003e\u003cstrong data-start=\"5801\" data-end=\"5807\"\u003eA:\u003c\/strong\u003e Yes, the System Sensor 2012J smoke alarm (Model 2012J) operates perfectly with a 12VDC power supply, making it suitable for residential installations requiring low-voltage smoke detection systems.\u003c\/p\u003e\n\u003chr data-start=\"6006\" data-end=\"6009\"\u003e\n\u003cp data-start=\"6011\" data-end=\"6265\"\u003e\u003cstrong data-start=\"6011\" data-end=\"6108\"\u003eQ2: How many System Sensor 2012J smoke alarms (Model 2012J) can I interconnect in one system?\u003c\/strong\u003e\u003cbr data-start=\"6108\" data-end=\"6111\"\u003e\u003cstrong data-start=\"6111\" data-end=\"6117\"\u003eA:\u003c\/strong\u003e You can interconnect up to 24 System Sensor 2012J smoke alarms (Model 2012J) for broader coverage across larger properties or multi-unit buildings.\u003c\/p\u003e\n\u003chr data-start=\"6267\" data-end=\"6270\"\u003e\n\u003cp data-start=\"6272\" data-end=\"6523\"\u003e\u003cstrong data-start=\"6272\" data-end=\"6356\"\u003eQ3: Does the System Sensor 2012J (Model 2012J) comply with Australian standards?\u003c\/strong\u003e\u003cbr data-start=\"6356\" data-end=\"6359\"\u003e\u003cstrong data-start=\"6359\" data-end=\"6365\"\u003eA:\u003c\/strong\u003e Yes, the System Sensor 2012J (Model 2012J) is AS 3786 listed, ensuring compliance with Australian smoke alarm regulations for residential and commercial use.\u003c\/p\u003e\n\u003chr data-start=\"6525\" data-end=\"6528\"\u003e\n\u003cp data-start=\"6530\" data-end=\"6864\"\u003e\u003cstrong data-start=\"6530\" data-end=\"6633\"\u003eQ4: What is the purpose of the Form ‘C’ relay in the System Sensor 2012J smoke alarm (Model 2012J)?\u003c\/strong\u003e\u003cbr data-start=\"6633\" data-end=\"6636\"\u003e\u003cstrong data-start=\"6636\" data-end=\"6642\"\u003eA:\u003c\/strong\u003e The Form ‘C’ relay in the System Sensor 2012J smoke alarm (Model 2012J) allows external devices, such as control panels or auxiliary alert systems, to be activated during an alarm, enhancing system integration and safety.\u003c\/p\u003e\n\u003chr data-start=\"6866\" data-end=\"6869\"\u003e\n\u003cp data-start=\"6871\" data-end=\"7131\"\u003e\u003cstrong data-start=\"6871\" data-end=\"6978\"\u003eQ5: Does the System Sensor 2012J smoke alarm (Model 2012J) have a hush feature to silence false alarms?\u003c\/strong\u003e\u003cbr data-start=\"6978\" data-end=\"6981\"\u003e\u003cstrong data-start=\"6981\" data-end=\"6987\"\u003eA:\u003c\/strong\u003e Yes, the System Sensor 2012J smoke alarm (Model 2012J) includes a HUSH feature to temporarily silence nuisance alarms while maintaining safety.\u003c\/p\u003e","brand":"CCTV Tradie","offers":[{"title":"Default Title","offer_id":44530380963943,"sku":"2012J-TW","price":90.78,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/8268\/2471\/files\/2012J.jpg?v=1788076888","url":"https:\/\/shop.underbrella.com.au\/products\/system-sensor-2012j-photoelectric-smoke-alarm-12-24vdc-interconnectable-form-c-relay-hush-feature-model-2012j","provider":"UnderBrella","version":"1.0","type":"link"}