{"product_id":"lockwood-es9000-preload-e-strike-10-30vdc-monitored","title":"Lockwood ES9000 PRELOAD E\/STRIKE 10-30VDC Monitored","description":"\u003cp\u003eThe Lockwood Padde Series ES9000 has been designed to suit the harshest commercial environments, and has the unique feature of the ability to operate with up to 25kg of pre-load pressure on the keeper. Pre-load is a common condition that is caused by pulling on a door before it unlocks, the weight of warped or drooping doors, seals on fire doors or by differential air pressure created when heating and cooling systems are in use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperates under pre load up to 25kg\u003c\/li\u003e\n\u003cli\u003eEasy field selectable fail safe\/fail secure\u003c\/li\u003e\n\u003cli\u003eMulti voltage 10-30Vdc\u003c\/li\u003e\n\u003cli\u003e1300kg holding force\u003c\/li\u003e\n\u003cli\u003e2.5 million cycles endurance rating\u003c\/li\u003e\n\u003cli\u003eLatch keeper is significantly quieter in operation\u003c\/li\u003e\n\u003cli\u003eWeather resistant\u003c\/li\u003e\n\u003cli\u003eMounting tabs as standard\u003c\/li\u003e\n\u003cli\u003eNon handed\u003c\/li\u003e\n\u003cli\u003eTRICARE® 5 Year Warranty\u003c\/li\u003e\n\u003cli\u003eWeather Resistant (IP54)\u003c\/li\u003e\n\u003cli\u003eBuilt in Protection Diode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh traffic areas\u003c\/li\u003e\n\u003cli\u003eDoors subjected to side load (pre load)\u003c\/li\u003e\n\u003cli\u003eFire rated door sets\u003c\/li\u003e\n\u003cli\u003eOpen in\/open out doors\u003c\/li\u003e\n\u003cli\u003eSuitable for use with all access control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/catalogue.pdf?v=1656132525\"\u003eDownload Catalogue\u003c\/a\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"height: 235.125px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 19.5938px;\"\u003eVideo\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 19.5938px;\"\u003e10 or 30Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 19.5938px;\"\u003eCurrent\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 19.5938px;\"\u003e\u003cspan\u003e250mA @12Vdc – 130mA @24Vdc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 19.5938px;\"\u003eSolenoids\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 19.5938px;\"\u003eSolenoids rated for continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 39.1875px;\"\u003eMonitoring\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 39.1875px;\"\u003eSolenoid Monitor - 1 amp NO\/NC microswitch Door \/ Latch - 1 amp NO\/NC microswitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 19.5938px;\"\u003eHolding Force\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 19.5938px;\"\u003e1300kg Static Strength Rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 39.1875px;\"\u003eEndurance\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 39.1875px;\"\u003e1,200,000 cycles endurance rating @ 25kg pre-load 2,500,00 cycles general durability without pre-load conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 19.5938px;\"\u003eLatching\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 19.5938px;\"\u003eSuitable for 15mm latch with 3mm door gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 19.5938px;\"\u003eEnvironment\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 19.5938px;\"\u003e Operational temperature range - 20C to +60C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 19.5938px;\"\u003eBody\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 19.5938px;\"\u003eSolid Stainless Steel Construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 16.6763%; height: 19.5938px;\"\u003eKeeper\u003c\/td\u003e\n\u003ctd style=\"width: 80.7407%; height: 19.5938px;\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-end=\"304\" data-start=\"112\"\u003eThe \u003cstrong data-end=\"181\" data-start=\"116\"\u003eLockwood ES9000 Preload Electric Strike (10–30VDC, Monitored)\u003c\/strong\u003e is a heavy-duty commercial electric strike designed for access control systems. All variants share the same core features:\u003c\/p\u003e\n\u003cul data-end=\"627\" data-start=\"306\"\u003e\n\u003cli data-end=\"384\" data-start=\"306\"\u003e\n\u003cp data-end=\"384\" data-start=\"308\"\u003ePre-load operation – works even with up to ~25 kg of pressure on the latch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"419\" data-start=\"385\"\u003e\n\u003cp data-end=\"419\" data-start=\"387\"\u003eMulti-voltage input: 10–30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"473\" data-start=\"420\"\u003e\n\u003cp data-end=\"473\" data-start=\"422\"\u003eField-selectable \u003cstrong data-end=\"452\" data-start=\"439\"\u003eFail Safe\u003c\/strong\u003e or \u003cstrong data-end=\"471\" data-start=\"456\"\u003eFail Secure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"531\" data-start=\"474\"\u003e\n\u003cp data-end=\"531\" data-start=\"476\"\u003eFull monitoring (solenoid status + door\/latch status)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"576\" data-start=\"532\"\u003e\n\u003cp data-end=\"576\" data-start=\"534\"\u003eHigh holding strength (commercial grade)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"627\" data-start=\"577\"\u003e\n\u003cp data-end=\"627\" data-start=\"579\"\u003eDesigned for high-traffic and commercial doors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"796\" data-start=\"629\"\u003eThe difference between the part numbers is \u003cstrong data-end=\"704\" data-start=\"672\"\u003enot electrical or functional\u003c\/strong\u003e — it is purely about the \u003cstrong data-end=\"760\" data-start=\"730\"\u003ephysical lip configuration\u003c\/strong\u003e to suit different door frame preps.\u003c\/p\u003e\n\u003chr data-end=\"801\" data-start=\"798\"\u003e\n\u003ch2 data-end=\"838\" data-start=\"803\"\u003e🆚 Variant Differences Explained\u003c\/h2\u003e\n\u003ch3 data-end=\"862\" data-start=\"840\"\u003e🔹 \u003cstrong data-end=\"860\" data-start=\"847\"\u003eAA-ES9000\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"977\" data-start=\"863\"\u003eStandard model with \u003cstrong data-end=\"902\" data-start=\"883\"\u003eno extended lip\u003c\/strong\u003e.\u003cbr data-end=\"906\" data-start=\"903\"\u003eUsed when the door frame is cut to standard electric strike dimensions.\u003c\/p\u003e\n\u003cp data-end=\"994\" data-start=\"979\"\u003e\u003cstrong data-end=\"992\" data-start=\"979\"\u003eBest for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1098\" data-start=\"995\"\u003e\n\u003cli data-end=\"1035\" data-start=\"995\"\u003e\n\u003cp data-end=\"1035\" data-start=\"997\"\u003eNew installs with correct frame prep\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1098\" data-start=\"1036\"\u003e\n\u003cp data-end=\"1098\" data-start=\"1038\"\u003eAluminium and steel frames already designed for ES strikes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1103\" data-start=\"1100\"\u003e\n\u003ch3 data-end=\"1151\" data-start=\"1105\"\u003e🔹 \u003cstrong data-end=\"1129\" data-start=\"1112\"\u003eAA-ES9000-020\u003c\/strong\u003e – 8 mm Extended Lip\u003c\/h3\u003e\n\u003cp data-end=\"1207\" data-start=\"1152\"\u003eIncludes an \u003cstrong data-end=\"1187\" data-start=\"1164\"\u003e8 mm protruding lip\u003c\/strong\u003e on the strike face.\u003c\/p\u003e\n\u003cp data-end=\"1224\" data-start=\"1209\"\u003e\u003cstrong data-end=\"1222\" data-start=\"1209\"\u003eBest for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1417\" data-start=\"1225\"\u003e\n\u003cli data-end=\"1280\" data-start=\"1225\"\u003e\n\u003cp data-end=\"1280\" data-start=\"1227\"\u003eFrames where the strike pocket is slightly recessed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1346\" data-start=\"1281\"\u003e\n\u003cp data-end=\"1346\" data-start=\"1283\"\u003eSituations where there is a larger gap between door and frame\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1417\" data-start=\"1347\"\u003e\n\u003cp data-end=\"1417\" data-start=\"1349\"\u003eRetrofit installs where the original cut-out is deeper than normal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1422\" data-start=\"1419\"\u003e\n\u003ch3 data-end=\"1483\" data-start=\"1424\"\u003e🔹 \u003cstrong data-end=\"1448\" data-start=\"1431\"\u003eAA-ES9000-060\u003c\/strong\u003e – Extended Lip with Fixing Holes\u003c\/h3\u003e\n\u003cp data-end=\"1538\" data-start=\"1484\"\u003eHas an \u003cstrong data-end=\"1537\" data-start=\"1491\"\u003eextended lip with pre-drilled fixing holes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1555\" data-start=\"1540\"\u003e\u003cstrong data-end=\"1553\" data-start=\"1540\"\u003eBest for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1724\" data-start=\"1556\"\u003e\n\u003cli data-end=\"1609\" data-start=\"1556\"\u003e\n\u003cp data-end=\"1609\" data-start=\"1558\"\u003eInstallations requiring extra mechanical strength\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1650\" data-start=\"1610\"\u003e\n\u003cp data-end=\"1650\" data-start=\"1612\"\u003eTimber frames or custom metal frames\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1724\" data-start=\"1651\"\u003e\n\u003cp data-end=\"1724\" data-start=\"1653\"\u003eSituations where you need to screw through the lip for a firmer mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1729\" data-start=\"1726\"\u003e\n\u003ch2 data-end=\"1753\" data-start=\"1731\"\u003e📌 Quick Comparison\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2282\" data-start=\"1755\"\u003e\n\u003cthead data-end=\"1860\" data-start=\"1755\"\u003e\n\u003ctr data-end=\"1860\" data-start=\"1755\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1776\" data-start=\"1755\"\u003eVariant\u003c\/th\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1811\" data-start=\"1776\"\u003ePhysical Difference\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"1860\" data-start=\"1811\"\u003eTypical Use Case\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2282\" data-start=\"1967\"\u003e\n\u003ctr data-end=\"2072\" data-start=\"1967\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1988\" data-start=\"1967\"\u003e\u003cstrong data-end=\"1982\" data-start=\"1969\"\u003eAA-ES9000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2023\" data-start=\"1988\" data-col-size=\"sm\"\u003eStandard face, no lip\u003c\/td\u003e\n\u003ctd data-end=\"2072\" data-start=\"2023\" data-col-size=\"md\"\u003eStandard frame prep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2177\" data-start=\"2073\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2094\" data-start=\"2073\"\u003e\u003cstrong data-end=\"2092\" data-start=\"2075\"\u003eAA-ES9000-020\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2129\" data-start=\"2094\" data-col-size=\"sm\"\u003e8 mm extended lip\u003c\/td\u003e\n\u003ctd data-end=\"2177\" data-start=\"2129\" data-col-size=\"md\"\u003eDeeper frame pockets \/ wider door gaps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2282\" data-start=\"2178\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2199\" data-start=\"2178\"\u003e\u003cstrong data-end=\"2197\" data-start=\"2180\"\u003eAA-ES9000-060\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-end=\"2234\" data-start=\"2199\" data-col-size=\"sm\"\u003eExtended lip with screw holes\u003c\/td\u003e\n\u003ctd data-end=\"2282\" data-start=\"2234\" data-col-size=\"md\"\u003eReinforced mounting \/ timber or custom frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2287\" data-start=\"2284\"\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"2529\" data-start=\"2289\"\u003eAll three versions perform \u003cstrong data-end=\"2331\" data-start=\"2316\"\u003eidentically\u003c\/strong\u003e electrically and mechanically — the only difference is how they physically sit in the door frame. The correct choice depends entirely on the door frame depth and how the strike needs to be mounted.\u003c\/p\u003e","brand":"CCTV Tradie","offers":[{"title":"AA-ES9000","offer_id":44530232459367,"sku":"ES90001030VDC-1","price":561.0,"currency_code":"AUD","in_stock":true},{"title":"AA-ES9000-020","offer_id":44530232492135,"sku":"ES90001030VDC-2","price":591.6,"currency_code":"AUD","in_stock":true},{"title":"AA-ES9000-060","offer_id":44530232524903,"sku":"ES90001030VDC-3","price":642.6,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/8268\/2471\/files\/ASSES9000010.jpg?v=1788074379","url":"https:\/\/shop.underbrella.com.au\/products\/lockwood-es9000-preload-e-strike-10-30vdc-monitored","provider":"UnderBrella","version":"1.0","type":"link"}