{"product_id":"bosch-b308-octo-output-expansion-module-8-programmable-relays-for-solution-2000-3000-4000-alarm-panels","title":"Bosch B308 Octo-Output Expansion Module – 8 Programmable Relays for Solution 2000\/3000\/4000 Alarm Panels","description":"\u003cp data-start=\"180\" data-end=\"693\" class=\"\"\u003eThe \u003cstrong data-start=\"184\" data-end=\"217\"\u003eBosch B308 Octo-Output Module\u003c\/strong\u003e delivers versatile and programmable output control for intrusion and fire alarm systems. Designed to integrate seamlessly with Bosch’s Solution 2000, 3000, and 4000 control panels, this expansion module offers eight independent Form C relays, each rated at 1 A @ 24 VDC. Whether you're managing HVAC systems, door locks, or emergency fire signaling devices, the B308 ensures robust and reliable relay switching under a wide range of building automation or security scenarios.\u003c\/p\u003e\n\u003cp data-start=\"180\" data-end=\"693\" class=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/Screenshot_2025-05-03_152619.png?v=1746250075\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp data-start=\"695\" data-end=\"1091\" class=\"\"\u003eIdeal for industrial, commercial, and institutional environments, the B308 enables advanced control and monitoring via its SDI2 bus connection. Relays can be activated by specific system events such as alarms, faults, or user commands through control panel keypads. Its compact design and easy-to-read switch addressing simplify installation and configuration, even for large multi-module setups.\u003c\/p\u003e\n\u003chr data-start=\"1093\" data-end=\"1096\" class=\"\"\u003e\n\u003ch3 data-start=\"1098\" data-end=\"1134\" class=\"\"\u003e\u003cstrong data-start=\"1102\" data-end=\"1132\"\u003eWhat’s Included in the Box\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1135\" data-end=\"1276\"\u003e\n\u003cli data-start=\"1135\" data-end=\"1172\" class=\"\"\u003e\n\u003cp data-start=\"1137\" data-end=\"1172\" class=\"\"\u003e1 x Bosch B308 Octo-Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1173\" data-end=\"1210\" class=\"\"\u003e\n\u003cp data-start=\"1175\" data-end=\"1210\" class=\"\"\u003e1 x Interconnect Wiring Connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1211\" data-end=\"1232\" class=\"\"\u003e\n\u003cp data-start=\"1213\" data-end=\"1232\" class=\"\"\u003e1 x Hardware Pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1233\" data-end=\"1276\" class=\"\"\u003e\n\u003cp data-start=\"1235\" data-end=\"1276\" class=\"\"\u003e1 x Installation \u0026amp; User Literature Pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1278\" data-end=\"1281\" class=\"\"\u003e\n\u003ch3 data-start=\"1283\" data-end=\"1306\" class=\"\"\u003e\u003cstrong data-start=\"1287\" data-end=\"1304\"\u003eMain Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1307\" data-end=\"1774\"\u003e\n\u003cli data-start=\"1307\" data-end=\"1350\" class=\"\"\u003e\n\u003cp data-start=\"1309\" data-end=\"1350\" class=\"\"\u003eEight programmable Form C relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1351\" data-end=\"1397\" class=\"\"\u003e\n\u003cp data-start=\"1353\" data-end=\"1397\" class=\"\"\u003eDry contact switching, rated 1 A at 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1398\" data-end=\"1451\" class=\"\"\u003e\n\u003cp data-start=\"1400\" data-end=\"1451\" class=\"\"\u003eSDI2 bus compatibility for reliable communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1452\" data-end=\"1507\" class=\"\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1507\" class=\"\"\u003eEasy switch addressing for simplified configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1508\" data-end=\"1559\" class=\"\"\u003e\n\u003cp data-start=\"1510\" data-end=\"1559\" class=\"\"\u003eRemote output control via control panel keypads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1643\" class=\"\"\u003e\n\u003cp data-start=\"1562\" data-end=\"1643\" class=\"\"\u003eSupports critical building system interfacing: HVAC, door release, annunciators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1644\" data-end=\"1704\" class=\"\"\u003e\n\u003cp data-start=\"1646\" data-end=\"1704\" class=\"\"\u003eScalable integration: up to 12 modules (panel-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1705\" data-end=\"1774\" class=\"\"\u003e\n\u003cp data-start=\"1707\" data-end=\"1774\" class=\"\"\u003eUL \u0026amp; FM approved for intrusion and fire alarm system applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0637\/2838\/6287\/files\/s-l1200_b36500bf-443d-48bc-9180-94fe2eb3bc76.jpg?v=1746250075\" alt=\"\"\u003e\u003c\/p\u003e\n\u003chr data-start=\"1776\" data-end=\"1779\" class=\"\"\u003e\n\u003ch3 data-start=\"1781\" data-end=\"1814\" class=\"\"\u003e\u003cstrong data-start=\"1785\" data-end=\"1812\"\u003eDetailed Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1815\" data-end=\"2444\"\u003e\n\u003cli data-start=\"1815\" data-end=\"1868\" class=\"\"\u003e\n\u003cp data-start=\"1817\" data-end=\"1868\" class=\"\"\u003e\u003cstrong data-start=\"1817\" data-end=\"1838\"\u003eModule Dimensions\u003c\/strong\u003e: 7.35 cm x 12.7 cm x 1.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1869\" data-end=\"1911\" class=\"\"\u003e\n\u003cp data-start=\"1871\" data-end=\"1911\" class=\"\"\u003e\u003cstrong data-start=\"1871\" data-end=\"1895\"\u003eRelay Contact Rating\u003c\/strong\u003e: 1 A @ 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1912\" data-end=\"1972\" class=\"\"\u003e\n\u003cp data-start=\"1914\" data-end=\"1972\" class=\"\"\u003e\u003cstrong data-start=\"1914\" data-end=\"1937\"\u003eRelay Configuration\u003c\/strong\u003e: Form C (Normally Open \u0026amp; Closed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1973\" data-end=\"2062\" class=\"\"\u003e\n\u003cp data-start=\"1975\" data-end=\"2062\" class=\"\"\u003e\u003cstrong data-start=\"1975\" data-end=\"1996\"\u003ePower Consumption\u003c\/strong\u003e: 150 mA max (22 mA digital section + 16 mA per energized relay)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2063\" data-end=\"2100\" class=\"\"\u003e\n\u003cp data-start=\"2065\" data-end=\"2100\" class=\"\"\u003e\u003cstrong data-start=\"2065\" data-end=\"2082\"\u003eVoltage Input\u003c\/strong\u003e: 12 VDC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2101\" data-end=\"2243\" class=\"\"\u003e\n\u003cp data-start=\"2103\" data-end=\"2129\" class=\"\"\u003e\u003cstrong data-start=\"2103\" data-end=\"2126\"\u003eWiring Requirements\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"2133\" data-end=\"2243\"\u003e\n\u003cli data-start=\"2133\" data-end=\"2173\" class=\"\"\u003e\n\u003cp data-start=\"2135\" data-end=\"2173\" class=\"\"\u003e22 AWG (0.65 mm): max 137 m (400 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2177\" data-end=\"2215\" class=\"\"\u003e\n\u003cp data-start=\"2179\" data-end=\"2215\" class=\"\"\u003e18 AWG (2 mm): max 305 m (1000 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2219\" data-end=\"2243\" class=\"\"\u003e\n\u003cp data-start=\"2221\" data-end=\"2243\" class=\"\"\u003eUnshielded wire only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2275\" class=\"\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2275\" class=\"\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2267\"\u003eBus Compatibility\u003c\/strong\u003e: SDI2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2276\" data-end=\"2444\" class=\"\"\u003e\n\u003cp data-start=\"2278\" data-end=\"2299\" class=\"\"\u003e\u003cstrong data-start=\"2278\" data-end=\"2296\"\u003eCertifications\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"2302\" data-end=\"2444\"\u003e\n\u003cli data-start=\"2302\" data-end=\"2325\" class=\"\"\u003e\n\u003cp data-start=\"2304\" data-end=\"2325\" class=\"\"\u003eFCC Part 15 Class B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2328\" data-end=\"2371\" class=\"\"\u003e\n\u003cp data-start=\"2330\" data-end=\"2371\" class=\"\"\u003eUL 365, 609, 1023, 1076, 1610, 864, 985\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2374\" data-end=\"2424\" class=\"\"\u003e\n\u003cp data-start=\"2376\" data-end=\"2424\" class=\"\"\u003eULC-S303, ULC-S304-06, ULC-ORD C1023, and more\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2427\" data-end=\"2444\" class=\"\"\u003e\n\u003cp data-start=\"2429\" data-end=\"2444\" class=\"\"\u003eCSFM Approved\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2446\" data-end=\"2449\" class=\"\"\u003e\n\u003ch3 data-start=\"2451\" data-end=\"2478\" class=\"\"\u003e\u003cstrong data-start=\"2455\" data-end=\"2476\"\u003eCompatible Panels\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2479\" data-end=\"2664\"\u003e\n\u003cli data-start=\"2479\" data-end=\"2514\" class=\"\"\u003e\n\u003cp data-start=\"2481\" data-end=\"2514\" class=\"\"\u003eBosch Solution 2000, 3000, 4000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2515\" data-end=\"2542\" class=\"\"\u003e\n\u003cp data-start=\"2517\" data-end=\"2542\" class=\"\"\u003eB5512 (up to 5 modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2543\" data-end=\"2570\" class=\"\"\u003e\n\u003cp data-start=\"2545\" data-end=\"2570\" class=\"\"\u003eB4512 (up to 3 modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2571\" data-end=\"2602\" class=\"\"\u003e\n\u003cp data-start=\"2573\" data-end=\"2602\" class=\"\"\u003eD9412GV4 (up to 12 modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2603\" data-end=\"2633\" class=\"\"\u003e\n\u003cp data-start=\"2605\" data-end=\"2633\" class=\"\"\u003eD7412GV4 (up to 6 modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2634\" data-end=\"2664\" class=\"\"\u003e\n\u003cp data-start=\"2636\" data-end=\"2664\" class=\"\"\u003eD7212GV4 (up to 2 modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2666\" data-end=\"2669\" class=\"\"\u003e\n\u003ch3 data-start=\"2671\" data-end=\"2701\" class=\"\"\u003e\u003cstrong data-start=\"2675\" data-end=\"2699\"\u003eWarranty Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2702\" data-end=\"2942\" class=\"\"\u003eBosch B308 modules come with a \u003cstrong data-start=\"2733\" data-end=\"2765\"\u003e3-year manufacturer warranty\u003c\/strong\u003e, covering defects in materials and workmanship. Warranty service is handled through authorized Bosch service centers or direct brand communication in Australia and New Zealand.\u003c\/p\u003e\n\u003chr data-start=\"2944\" data-end=\"2947\" class=\"\"\u003e\n\u003ch3 data-start=\"2949\" data-end=\"2976\" class=\"\"\u003e\u003cstrong data-start=\"2953\" data-end=\"2974\"\u003eBrand Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2977\" data-end=\"3264\" class=\"\"\u003e\u003cstrong data-start=\"2977\" data-end=\"3003\"\u003eBosch Security Systems\u003c\/strong\u003e is a global leader in innovative security and safety solutions. Known for high-quality engineering and cutting-edge technologies, Bosch delivers trusted systems tailored for a wide range of industries—from residential to commercial and industrial environments.\u003c\/p\u003e\n\u003chr data-start=\"3266\" data-end=\"3269\" class=\"\"\u003e\n\u003ch3 data-start=\"3271\" data-end=\"3284\" class=\"\"\u003e\u003cstrong data-start=\"3275\" data-end=\"3282\"\u003eSKU\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3285\" data-end=\"3293\" class=\"\"\u003e\u003cstrong data-start=\"3285\" data-end=\"3293\"\u003eB308\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"3295\" data-end=\"3298\" class=\"\"\u003e\n\u003ch3 data-start=\"3300\" data-end=\"3333\" class=\"\"\u003e\u003cstrong data-start=\"3304\" data-end=\"3331\"\u003ePractical Use Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3334\" data-end=\"3770\"\u003e\n\u003cli data-start=\"3334\" data-end=\"3415\" class=\"\"\u003e\n\u003cp data-start=\"3336\" data-end=\"3415\" class=\"\"\u003e\u003cstrong data-start=\"3336\" data-end=\"3358\"\u003eFire Alarm Systems\u003c\/strong\u003e: Activate remote annunciators or display system status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3416\" data-end=\"3498\" class=\"\"\u003e\n\u003cp data-start=\"3418\" data-end=\"3498\" class=\"\"\u003e\u003cstrong data-start=\"3418\" data-end=\"3441\"\u003eBuilding Automation\u003c\/strong\u003e: Interface with HVAC systems, lighting, and door locks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3499\" data-end=\"3586\" class=\"\"\u003e\n\u003cp data-start=\"3501\" data-end=\"3586\" class=\"\"\u003e\u003cstrong data-start=\"3501\" data-end=\"3521\"\u003eSecurity Systems\u003c\/strong\u003e: Trigger alarms or alerts based on system faults or intrusions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3587\" data-end=\"3673\" class=\"\"\u003e\n\u003cp data-start=\"3589\" data-end=\"3673\" class=\"\"\u003e\u003cstrong data-start=\"3589\" data-end=\"3618\"\u003eCommercial Access Control\u003c\/strong\u003e: Remotely control output devices like magnetic locks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3674\" data-end=\"3770\" class=\"\"\u003e\n\u003cp data-start=\"3676\" data-end=\"3770\" class=\"\"\u003e\u003cstrong data-start=\"3676\" data-end=\"3708\"\u003eIndustrial Safety Compliance\u003c\/strong\u003e: Automate emergency ventilation or stairwell pressurization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3772\" data-end=\"3775\" class=\"\"\u003e\n\u003ch3 data-start=\"3777\" data-end=\"3823\" class=\"\"\u003e\u003cstrong data-start=\"3781\" data-end=\"3821\"\u003eDatasheets or Downloadable Resources\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"downloads\"\u003e\n\u003cli class=\"download suffix-1pdf\"\u003e\u003ca href=\"https:\/\/d347awuzx0kdse.cloudfront.net\/netdigital\/product-download\/b308_1.pdf?v=094a22ab1309041781e440a235537abf424c5c87\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"download suffix-2pdf\"\u003e\u003ca href=\"https:\/\/d347awuzx0kdse.cloudfront.net\/netdigital\/product-download\/b308_2.pdf?v=1895a860d2b0befe47ed4645f19361ece0b7c8b3\" target=\"_blank\"\u003eDownload Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"download suffix-6pdf\"\u003e\u003ca href=\"https:\/\/d347awuzx0kdse.cloudfront.net\/netdigital\/product-download\/b308_6.pdf?v=9f5b5a44be4521bef8a6d9f0d3e2b708575e1274\" target=\"_blank\"\u003eDownload Misc Document 1\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4022\" data-end=\"4025\" class=\"\"\u003e\n\u003ch3 data-start=\"4027\" data-end=\"4089\" class=\"\"\u003e\u003cstrong data-start=\"4031\" data-end=\"4087\"\u003eExcellence for the Australian and New Zealand Market\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4090\" data-end=\"4493\"\u003e\n\u003cli data-start=\"4090\" data-end=\"4177\" class=\"\"\u003e\n\u003cp data-start=\"4092\" data-end=\"4177\" class=\"\"\u003eFully \u003cstrong data-start=\"4098\" data-end=\"4175\"\u003ecompliant with Australian and New Zealand safety and electrical standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4178\" data-end=\"4243\" class=\"\"\u003e\n\u003cp data-start=\"4180\" data-end=\"4243\" class=\"\"\u003eSourced \u003cstrong data-start=\"4188\" data-end=\"4241\"\u003eexclusively through authorized Bosch distributors\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4244\" data-end=\"4321\" class=\"\"\u003e\n\u003cp data-start=\"4246\" data-end=\"4321\" class=\"\"\u003e\u003cstrong data-start=\"4246\" data-end=\"4271\"\u003eNDSS and UL certified\u003c\/strong\u003e for high-reliability fire and intrusion systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4322\" data-end=\"4389\" class=\"\"\u003e\n\u003cp data-start=\"4324\" data-end=\"4389\" class=\"\"\u003eBacked by Bosch’s \u003cstrong data-start=\"4342\" data-end=\"4387\"\u003elocal support and direct warranty service\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4390\" data-end=\"4493\" class=\"\"\u003e\n\u003cp data-start=\"4392\" data-end=\"4493\" class=\"\"\u003eOptimized for \u003cstrong data-start=\"4406\" data-end=\"4469\"\u003euse in industrial, commercial, and institutional facilities\u003c\/strong\u003e common in ANZ markets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4495\" data-end=\"4498\" class=\"\"\u003e\n\u003ch3 data-start=\"4500\" data-end=\"4541\" class=\"\"\u003e\u003cstrong data-start=\"4504\" data-end=\"4541\"\u003eFrequently Asked Questions (FAQs)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4543\" data-end=\"4799\" class=\"\"\u003e\u003cstrong data-start=\"4543\" data-end=\"4632\"\u003eQ1: Is the Bosch B308 (Product Code: B308) compatible with all Bosch Solution panels?\u003c\/strong\u003e\u003cbr data-start=\"4632\" data-end=\"4635\"\u003e\u003cstrong data-start=\"4635\" data-end=\"4642\"\u003eA1:\u003c\/strong\u003e Yes, the B308 is fully compatible with Bosch Solution 2000, 3000, and 4000 panels as well as B and GV4 series control panels for broader system integration.\u003c\/p\u003e\n\u003cp data-start=\"4801\" data-end=\"5034\" class=\"\"\u003e\u003cstrong data-start=\"4801\" data-end=\"4885\"\u003eQ2: What type of output relays does the Bosch B308 (Product Code: B308) provide?\u003c\/strong\u003e\u003cbr data-start=\"4885\" data-end=\"4888\"\u003e\u003cstrong data-start=\"4888\" data-end=\"4895\"\u003eA2:\u003c\/strong\u003e The B308 provides eight Form C relays, each offering both normally open and normally closed contact configurations, rated at 1 A @ 24 VDC.\u003c\/p\u003e\n\u003cp data-start=\"5036\" data-end=\"5221\" class=\"\"\u003e\u003cstrong data-start=\"5036\" data-end=\"5110\"\u003eQ3: Can I control the Bosch B308 (Product Code: B308) relays remotely?\u003c\/strong\u003e\u003cbr data-start=\"5110\" data-end=\"5113\"\u003e\u003cstrong data-start=\"5113\" data-end=\"5120\"\u003eA3:\u003c\/strong\u003e Yes, relays on the B308 can be programmed for remote control through compatible Bosch panel keypads.\u003c\/p\u003e\n\u003cp data-start=\"5223\" data-end=\"5443\" class=\"\"\u003e\u003cstrong data-start=\"5223\" data-end=\"5305\"\u003eQ4: How many Bosch B308 (Product Code: B308) modules can be added to a system?\u003c\/strong\u003e\u003cbr data-start=\"5305\" data-end=\"5308\"\u003e\u003cstrong data-start=\"5308\" data-end=\"5315\"\u003eA4:\u003c\/strong\u003e Depending on the control panel model, you can connect up to 12 B308 modules. For example, the D9412GV4 supports up to 12 units.\u003c\/p\u003e\n\u003cp data-start=\"5445\" data-end=\"5688\" class=\"\"\u003e\u003cstrong data-start=\"5445\" data-end=\"5542\"\u003eQ5: Is the Bosch B308 (Product Code: B308) approved for fire alarm applications in Australia?\u003c\/strong\u003e\u003cbr data-start=\"5542\" data-end=\"5545\"\u003e\u003cstrong data-start=\"5545\" data-end=\"5552\"\u003eA5:\u003c\/strong\u003e Yes, the B308 holds UL 864 and CSFM certifications and is suitable for fire alarm system integrations within Australia and New Zealand\u003c\/p\u003e","brand":"CCTV Tradie","offers":[{"title":"Default Title","offer_id":44530222465127,"sku":"BB308-NET","price":229.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/8268\/2471\/files\/b308.jpg?v=1788074257","url":"https:\/\/shop.underbrella.com.au\/products\/bosch-b308-octo-output-expansion-module-8-programmable-relays-for-solution-2000-3000-4000-alarm-panels","provider":"UnderBrella","version":"1.0","type":"link"}